Cài đặt biến tần A1000 cho ứng dụng chạy biến trở ngoài

15/10/2025

Bảng chi tiết cài đặt biến tần A1000 cho ứng dụng chạy biến trở ngoài

Thông sốMô tảCài đặtMặc định
AInitialization
A1-02Control Method Selection[0] V/f Control for Induction Motors*[2] Open Loop Vector Control
A1-06Application Preset[0] General*[0] General
BApplication
B1-01Frequency Reference Selection 1[0] Digital Operater*[1] Control Circuit Terminal
B1-02Operation method selection[1] Control circuit terminal*[1] Control circuit terminal
B1-03Stopping method[0] Deceleration*[0] Deceleration
B1-04Reverse operation[0] Reverse enable*[0] Reverse enable
CTuning
C1-01Acceleration time 12.0 sec*10.0 sec
C1-02Deceleration time 13.0 sec*10.0 sec
C1-09Emergency stop time10 sec*10 sec
C6-01Duty cycle[0] High heavy*[1] Normal heavy
C6-02Carrier frequency selection[02] Fc = 5.0 Hz*[07] Swing-PWM1
DReference Settings
D1-01Frequency reference 10 Hz*0 Hz
D1-02Frequency reference 20 Hz*0 Hz
D1-03Frequency reference 30 Hz*0 Hz
D1-04Frequency reference 40 Hz*0 Hz
D1-05Frequency reference 50 Hz*0 Hz
D1-06Frequency reference 60 Hz*0 Hz
D1-07Frequency reference 70 Hz*0 Hz
D1-08Frequency reference 80 Hz*0 Hz
D1-09Frequency reference 90 Hz*0 Hz
EMotor Prameter
E1-01Input voltage setting400 VAC*400 VAC
E1-03V/f pattern selection[0F] User-defined V/f pattern*[0F] User-defined V/f pattern
E1-04Max. output Frequency50.0 Hz*60.0 Hz
E1-05Max. voltage400 VAC*400 VAC
E1-06Base frequency50 Hz*60 Hz
E2-01Motor reted current--- A*--- A
E2-04Number of motor poles--- Pole*--- Pole
E2-11Motor rated output--- KW*--- KW
HTerminal Function Selection
H1-01Terminal S1 funtion selection[40] Forward run command*[40]
H1-02Terminal S2 funtion selection[41] Reverse run command*[41]
H1-03Terminal S3 funtion selection[0F] Not used*[24]
H1-04Terminal S4 funtion selection[0F] Not used*[14]
H1-05Terminal S5 funtion selection[0F] Not used*[03]
H1-06Terminal S6 funtion selection[0F] Not used*[04]
H1-07Terminal S7 funtion selection[0F] Not used*[06]
H1-08Terminal S8 funtion selection[0F] Not used*[08]
H2-01Terminal M1/M2 Selection[001A]*[000] Closed: Output frequency is greater than or equal to value in L4-04 with hysteresis determined by L4-02
H2-02Terminal M3/M4 Selection[001]*[001] Output frequency is zero
H2-03Terminal M5/M6 Selection[002]*[002] Outout frequency equals the speed reference
H3-01Terminal A1 signal level selection[0] 0 - 10V*[0] 0 - 10V
H3-02Terminal A1 Funciton selection[0D] Frequency Bias*[00] Frequency Bias
H3-03Terminal A1 gain setting100 %*100 %
H3-04Terminal A1 bias setting0 %*0 %
H3-06Terminal A3 Funciton selection[0F] Not used*[02] Auxiliary frequency reference 1
H3-10Terminal A2 Funciton selection[0F] Not used*[00] Frequency Bias
LProtection function selection
L3-04Stallp decelerarion selection[0] Disabled*[1] General purpose
L8-10Cooling fan control selection[0] Operates when inverter is running*[0] Operates when inverter is running