Cài đặt biến tần A1000 cho ứng dụng xe lớn cẩu trục

15/10/2025

Yêu cầu:

  • Điều khiển hai motor 2 bên dần cẩu trục 0.14/0.65Kw; 380-415V; 50 Hz;620/2750rpm/min; 0.68/1.68A. Cos Phi 0.67/0.86; IP 55.
  • Chạy hai cấp tốc độ cố định: Cấp tốc độ 1 chạy 13Hz; cấp tốc độ 2 chạy 50Hz.
  • Khởi động và dừng theo Ramp thông qua điện trở xả.
Thông sốMô tảCài đặtMặc định
AInitialization
A1-02Control Method Selection[0] V/f Control for Induction Motors*[2] Open Loop Vector Control
A1-06Application Preset[7] Crane*[0] General
BApplication
B1-01Frequency Reference Selection 1[0] Digital Operater*[1] Control Circuit Terminal
B1-02Operation method selection[1] Control circuit terminal*[1] Control circuit terminal
B1-03Stopping method[0] Deceleration*[0] Deceleration
CTuning
C1-01Acceleration time 12.0 sec*10.0 sec
C1-02Deceleration time 13.0 sec*10.0 sec
DReference Settings
D1-01Frequency reference 113 Hz*0 Hz
D1-02Frequency reference 250 Hz*0 Hz
D1-03Frequency reference 30 Hz*0 Hz
D1-04Frequency reference 40 Hz*0 Hz
D1-05Frequency reference 50 Hz*0 Hz
D1-06Frequency reference 60 Hz*0 Hz
D1-07Frequency reference 70 Hz*0 Hz
D1-08Frequency reference 80 Hz*0 Hz
D1-09Frequency reference 90 Hz*0 Hz
EMotor Prameter
E1-01Input voltage setting400 VAC*400 VAC
E1-04Max. output Frequency50.0 Hz*60.0 Hz
E1-05Max. voltage400 VAC*400 VAC
E1-06Base frequency50 Hz*60 Hz
E2-01Motor reted current3.4 A*---
E2-04Number of motor poles2*4
HTerminal Function Selection
H1-01Terminal S1 funtion selection[40] Forward run command*[40]
H1-02Terminal S2 funtion selection[41] Reverse run command*[41]
H1-03Terminal S3 funtion selection[03] Multi-step speed reference 1*[24]
H1-04Terminal S4 funtion selection[0F] Not used*[14]
H1-05Terminal S5 funtion selection[0F] Not used*[03]
H1-06Terminal S6 funtion selection[0F] Not used*[04]
H1-07Terminal S7 funtion selection[0F] Not used*
H1-08Terminal S8 funtion selection[0F] Not used*
H2-01Terminal M1/M2 Selection[0005]*[000] Closed: Output frequency is greater than or equal to value in L4-04 with hysteresis determined by L4-02
H2-02Terminal M3/M4 Selection[001]*[001] Output frequency is zero
H2-03Terminal M5/M6 Selection[002]*[002] Outout frequency equals the speed reference
H3-02Terminal A1 Funciton selection[0F] Not used*[00] Frequency Bias
H3-06Terminal A3 Funciton selection[0F] Not used*[02] Auxiliary frequency reference 1
H3-10Terminal A2 Funciton selection[0F] Not used*[00] Frequency Bias
LProtection function selection
L3-04Stallp decelerarion selection[0] Disabled*[1] General purpose
L4-01Speed agreement level6 Hz*0 Hz
L4-02Speed agreement width0 Hz*2 Hz
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.